Skip to content

Your first upgrade ​

This page takes you from an empty orchestrator to a finished upgrade job, one stage at a time. Each stage names what you do and links to the page that explains every field and message. Use it the first time, or as a checklist later.

Before you start ​

You needWhere to check
A Cloud account in your organizationAn Organization Admin invites you. See Signing in
A passkey for the orchestratorAdded from Cloud. See Signing in
A role that fits the stageThe table below, and Roles
An inventory source (NetBox or Infrahub) with the devices in itYour inventory team
The firmware file, obtained through your vendor channelFrameworkOps does not download firmware
StageRole at the orchestrator
Connect the inventory source, device credentials, driversOrchestrator administrator or Integration administrator
Upload and approve firmware, plan the job, run pre-checksOrchestrator administrator or Network operator
Approve, launch and control the rollout, decide on rollbackOrchestrator administrator

Everything below happens at the orchestrator, unless the step says Cloud.

1. Sign in to the orchestrator ​

  1. In Cloud, open the Dashboard and select the open-in-new-tab icon beside the orchestrator.
  2. On the orchestrator's sign-in page, select Continue with passkey.

If you have no passkey for this orchestrator yet, add one first from Orchestrator connection in Cloud. See Signing in.

2. Connect the inventory source ​

  1. Open Integrations and add your inventory source.
  2. Give it the address and a read-only token, choose what it covers, and finish the setup.
  3. Run the first sync with Sync now and wait for it to finish.

The devices now appear in the Device list. FrameworkOps only reads the inventory source; it never writes to it. See Integrations and Inventory sync.

3. Check that the devices can be upgraded ​

  1. Open the Device list.
  2. Open one of the devices you plan to upgrade and select the Readiness checks tab.
  3. Check that the device has a driver and device credentials.

A device without a driver or without credentials cannot be upgraded. See Device details, Drivers, and Inventory and integrations when something is missing.

4. Upload and approve the firmware ​

  1. Open Firmware packages and select Upload package.
  2. Choose the device model, upload the file and confirm that your organization is authorized to use it.
  3. Review the metadata and the compatibility mapping, then submit.
  4. Open the package and approve it.

Only an approved package can be chosen in an upgrade job. See Uploading a package and Approving and revoking.

5. Plan the job ​

Start small: one or two lab devices.

  1. In the Device list, select the devices and select Create upgrade job.
  2. Scope: name the job and check the selection.
  3. Firmware Package: choose the package until every device has one.
  4. Pre-checks: read what will be checked. Nothing runs yet.
  5. Strategy & Schedule: set the batch size, the auto-stop thresholds, the rollback mode and when the upgrade runs. Type a change reason and select Save plan and open pre-checks.

See Planning an upgrade.

6. Run the pre-checks ​

  1. On the job's Pre-checks step, select Run required pre-checks, give a reason and confirm.
  2. Wait for the results.
  3. Fix every blocker, or remove the blocked device from the plan, and run the pre-checks again.
  4. Read each warning. Acknowledge it only when you accept the risk it names.

A plan with a blocker cannot be launched. See Pre-checks and Troubleshooting pre-checks.

7. Approve and launch ​

  1. Open the Review & Launch step and read the plan: devices, packages, batches, auto-stop, start time and rollback.
  2. Select Approve execution, give a reason and confirm with your passkey.
  3. Select Launch rollout, read the dialog and confirm with your passkey.

WARNING

Launch is the point where real devices change. Until you confirm the launch, nothing has been done to any device.

The job starts at once or waits for its planned start. See Scheduling and launching.

8. Watch it run ​

The job page shows the waves Lab, Canary and Production, the batches and each device's steps. The rollout runs at the orchestrator, so you can close the browser and come back.

After each batch the job compares the failures with the auto-stop thresholds. When a threshold is reached, the job stops and asks you what to do. See Monitoring a running job and Stops and rollback.

9. Read the result ​

  1. When the job has ended, read each device's outcome on the job page.
  2. Export the job report when you need it for a change record.
  3. In Cloud, the Dashboard and Upgrade jobs show the result after the next sync with the orchestrator.

See Results and reports.

After the first job ​

  • Widen the scope: more devices, and waves that go from Lab through Canary to Production.
  • Save device groups for scopes you use again. See Device groups.
  • Set up alert rules so that a failed or stopped job reaches the right people. See Alert rules.